Nome da marca: | Hejin |
Número do modelo: | HJ190 |
MOQ: | 1 set |
preço: | Negociável |
Condições de pagamento: | L/C, T/T |
Capacidade de abastecimento: | 10 sets per month |
Relay Automatic Helium Inspection Line IEC 60068-2-17 Standard Helium Leakage Rate ≤1×10⁻⁹ Pa·M³/S Automated Inspection Efficiency ≥ 98%
Product Description
The HJ190 Relay Test Bench is a high-precision, fully automated helium leak detection system designed for high-volume relay production testing. It utilizes advanced mass spectrometry helium testing technology to ensure that every relay meets stringent sealing and safety standards before shipment.
Product Applications
This equipment is widely used in automotive electronics, rail transportation, power control, aerospace, and other fields. It is ideal for testing the leak tightness of relays, sensors, and other precision components, ensuring long-term stable operation in extreme environments such as high humidity, low temperature, and high pressure.
Product Highlights
High-Speed Testing: Fully automated assembly line operation, single-station testing time ≤ 6 seconds, significantly improving production capacity.
High Sensitivity: Detection limit reaches 1×10⁻⁹ Pa·m³/s, accurately identifying even the smallest leaks.
Intelligent Management: PLC control + industrial touchscreen operation, supporting independent control and data traceability for multiple stations.
Modular Design: Easy upgrade and maintenance, with customized testing parameters.
Energy-Saving and Environmentally Friendly: Helium recovery rate reaches up to 95%, reducing operating costs.
International Reference Standards
Standard No. |
Standard Name |
Applicable Clauses |
Description |
---|---|---|---|
IEC 60068-2-17 |
Environmental Testing – Part 2-17: Tests – Test Q: Sealing |
Clause 6~8 |
Specifies helium leak test methods and performance requirements |
ISO 20485 |
Non-destructive Testing – Helium Mass Spectrometer Leak Detection Method |
Clause 4~7 |
Standards for helium test sensitivity and test methods |
MIL-STD-883 |
Test Method Standard – Microcircuits |
Method 1014 |
Requirements for hermeticity testing |
ASTM E498/E499 |
Standard Test Method for Mass Spectrometer Leak Detection |
Clause 5~6 |
Defines calibration and testing methods for helium leak detection equipment |
Technical Parameters
Item |
Specification |
---|---|
Model |
HJ190 |
Detection Method |
Mass spectrometer helium leak detection |
Detection Range |
1×10⁻⁹ ~ 1×10⁻³ Pa·m³/s |
Single Station Test Time |
≤ 6 seconds |
Production Efficiency |
≥ 98% detection efficiency |
Number of Stations |
6~12 stations optional |
Helium Recovery Rate |
≥ 95% |
Control System |
Siemens PLC + industrial touch screen |
Data Management |
Automatic storage of test records, supports Excel export |
Power Supply |
AC 220V / 50Hz |
Air Supply Pressure |
0.5 ~ 0.7 MPa |
Dimensions |
Customized as required |
Weight |
Approx. 1500 kg |